Not to be confused with List of civilian nuclear incidents.
This article lists notable civilian accidents involving fissile nuclear material or nuclear reactors. Civilian incidents not serious enough to be accidents are listed at List of civilian nuclear incidents. Military accidents are listed at List of military nuclear accidents. Civil radiation accidents not involving fissile material are listed at List of civilian radiation accidents. For a general discussion of both civilian and military accidents, see Nuclear and radiation accidents.See also: Lists of nuclear disasters and radioactive incidents
Contents
|
Scope of this article
In listing civilian nuclear accidents, the following criteria have been followed:- There must be well-attested and substantial health damage, property damage or contamination.
- The damage must be related directly to radioactive material, not merely (for example) at a nuclear power plant.
- To qualify as "civilian", the nuclear operation/material must be principally for non-military purposes.
- The event should involve fissile material or a reactor.
1950s
- December 12, 1952 — INES Level 5[citation needed] - Chalk River, Ontario, Canada - Reactor core damaged
- A reactor shutoff rod failure, combined with several operator errors, led to a major power excursion of more than double the reactor's rated output at AECL's NRX reactor. The operators purged the reactor's heavy water moderator, and the reaction stopped in under 30 seconds. A cover gas system failure led to hydrogen explosions, which severely damaged the reactor core. The fission products from approximately 30 kg of uranium were released through the reactor stack. Irradiated light-water coolant leaked from the damaged coolant circuit into the reactor building; some 4,000 cubic meters were pumped via pipeline to a disposal area to avoid contamination of the Ottawa River. Subsequent monitoring of surrounding water sources revealed no contamination. No immediate fatalities or injuries resulted from the incident; a 1982 followup study of exposed workers showed no long-term health effects. Future U.S. President Jimmy Carter, then a Lieutenant in the US Navy, was among the cleanup crew.[1]
- May 24, 1958 — INES Level needed - Chalk River, Ontario, Canada - Fuel damaged
- Due to inadequate cooling a damaged uranium fuel rod caught fire and was torn in two as it was being removed from the core at the NRU reactor. The fire was extinguished, but not before radioactive combustion products contaminated the interior of the reactor building and, to a lesser degree, an area surrounding the laboratory site. Over 600 people were employed in the clean-up.
- October 25, 1958 - INES Level needed - Vinča, Yugoslavia - Criticality excursion, irradiation of personnel
- During a subcritical counting experiment a power buildup went undetected at the Vinca Nuclear Institute's zero-power natural uranium heavy water moderated research reactor.[4] Saturation of radiation detection chambers gave the researchers false readings and the level of moderator in the reactor tank was raised triggering a criticality excursion which a researcher detected from the smell of ozone.[5] Six scientists received radiation doses of 2—4 Sv (200—400 rems) [6] (p. 96). An experimental bone marrow transplant treatment was performed on all of them in France and five survived, despite the ultimate rejection of the marrow in all cases. A single woman among them later had a child without apparent complications. This was one of the first nuclear incidents investigated by then newly-formed IAEA.[7]
- July 26, 1959 — INES Level needed - Santa Susana Field Laboratory, California, United States - Partial meltdown
- A partial core meltdown may have taken place when the Sodium Reactor Experiment (SRE) experienced a power excursion that caused severe overheating of the reactor core, resulting in the melting of one-third of the nuclear fuel and significant releases of radioactive gases.[8]
1960s
- July 24, 1964 - INES Level needed - Charlestown, Rhode Island, United States - Criticality Accident
-
- An error by a worker at a United Nuclear Corporation fuel facility led to an accidental criticality. Robert Peabody, believing he was using a diluted uranium solution, accidentally put concentrated solution into an agitation tank containing sodium carbonate. Peabody was exposed to 10,000rad (100Gy) of radiation and died two days later. Ninety minutes after the criticality, a plant manager and another administrator returned to the building and were exposed to 100rad (1Gy), but suffered no ill effects.
- October 5, 1966 — INES Level needed - Monroe, Michigan, United States - Partial meltdown
-
- A sodium cooling system malfunction caused a partial meltdown at the Enrico Fermi demonstration nuclear breeder reactor (Enrico Fermi-1 fast breeder reactor). The accident was attributed to a zirconium fragment that obstructed a flow-guide in the sodium cooling system. Two of the 105 fuel assemblies melted during the incident, but no contamination was recorded outside the containment vessel.
- Winter 1966-1967 (date unknown) – INES Level needed – location unknown – loss of coolant accident
- The Soviet icebreaker Lenin, the USSR’s first nuclear-powered surface ship, suffered a major accident (possibly a meltdown — exactly what happened remains a matter of controversy in the West) in one of its three reactors. To find the leak the crew broke through the concrete and steel radiation shield with sledgehammers, causing irreparable damage. It was rumored that around 30 of the crew were killed. The ship was abandoned for a year to allow radiation levels to drop before the three reactors were removed, to be dumped into the Tsivolko Fjord on the Kara Sea, along with 60% of the fuel elements packed in a separate container. The reactors were replaced with two new ones, and the ship re-entered service in 1970, serving until 1989.
- May 1967 — INES Level needed - Dumfries and Galloway, Scotland, United Kingdom - Partial meltdown
- January 21, 1969 — INES Level needed - Lucens, Canton of Vaud, Switzerland - Explosion
-
- A total loss of coolant led to a power excursion and explosion of an experimental nuclear reactor in a large cave at Lucens. The underground location of this reactor acted like a containment building and prevented any outside contamination. The cavern was heavily contaminated and was sealed. No injuries or fatalities resulted.
1970s
- December 7, 1975 – INES Level 3 - Greifswald, Germany (then East Germany) - Partly damaged
-
- Operators disabled three of six cooling pumps' electrical supply circuits to test emergency shutoffs. Instead of the expected automatic shutdown, a fourth pump failed causing excessive heating which damaged ten fuel rods. The accident was attributed to sticky relay contacts and generally poor construction in the Soviet-built reactor.
- February 22, 1977 – INES Level 4 - Jaslovské Bohunice, Czechoslovakia - Fuel damaged
-
- Operators neglected to remove moisture-absorbing materials from a fuel rod assembly before loading it into the KS 150 reactor at power plant A-1. The accident resulted in damaged fuel integrity, extensive corrosion damage of fuel cladding and release of radioactivity into the plant area. The affected reactor was decommissioned following this accident.
- March 28, 1979 – INES Level 5[citation needed] - Middletown, Dauphin County, Pennsylvania, United States - Partial meltdown
-
- Equipment failures and worker mistakes contributed to a loss of coolant and a partial core meltdown at the Three Mile Island Nuclear Generating Station 15 km (9 miles) southeast of Harrisburg. While the reactor was extensively damaged, on-site radiation exposure was under 100 millirems (less than annual exposure due to natural sources). Area residents received a smaller exposure of 1 millirem (10 µSv), or about 1/3 the dose from eating a banana per day for one year. There were no fatalities. Follow-up radiological studies predict between zero and one long-term cancer fatality.
- See also: Three Mile Island accident
1980s
- March 13, 1980 - INES Level 4 - Orléans, France - Nuclear materials leak
- March, 1981 — INES Level 2 - Tsuruga, Japan - Radioactive materials released into Sea of Japan + Overexposure of workers
- January 25, 1982 - INES Level unknown - Ontario, New York - Radioactive materials released
-
- A steam pipe burst at the Ginna Nuclear Generating Station, resulting in a loss of coolant and gasses were intentionally vented to the atmosphere to reduce risks of explosion.
- September 23, 1983 — INES Level 4 - Buenos Aires, Argentina - Accidental criticality
-
- An operator error during a fuel plate reconfiguration in an experimental test reactor led to an excursion of 3×1017 fissions at the RA-2 facility. The operator absorbed 2000 rad (20 Gy) of gamma and 1700 rad (17 Gy) of neutron radiation which killed him two days later. Another 17 people outside of the reactor room absorbed doses ranging from 35 rad (0.35 Gy) to less than 1 rad (0.01 Gy).[ pg103
- April 26, 1986 — INES Level 7 - Prypiat, Ukraine (then USSR) - Power excursion, explosion, complete meltdown
-
- An inadequate reactor safety system led to an uncontrolled power excursion, causing a severe steam explosion, meltdown and release of radioactive material at the Chernobyl nuclear power plant located approximately 100 kilometers north-northwest of Kiev. Approximately fifty fatalities (mostly cleanup personnel) resulted from the accident and the immediate aftermath. An additional nine fatal cases of thyroid cancer in children in the Chernobyl area have been attributed to the accident. The explosion and combustion of the graphite reactor core spread radioactive material over much of Europe. 100,000 people were evacuated from the areas immediately surrounding Chernobyl in addition to 300,000 from the areas of heavy fallout in Ukraine, Belarus and Russia. An "Exclusion Zone" was created surrounding the site encompassing approximately 1,000 mi² (3,000 km²) and deemed off-limits for human habitation for an indefinite period. Several studies by governments, UN agencies and environmental groups have estimated the consequences and eventual number of casualties. Their findings are subject to controversy.
- See also: Chernobyl disaster
- May 4, 1986 – INES Level needed - Hamm-Uentrop, Germany (then West Germany) - Fuel damaged
- October 19, 1989 – INES Level 3 - Vandellos Nuclear Power Plant, Spain -fire in one of its two turbogenerators
-
- After the fire in the turbogenerators the Spanish comission determined a large list of issues in the plant that was closed by the owners due to economical unviability.
1990s
- April 6, 1993 — INES Level 4 - Tomsk, Russia - Explosion
-
- A pressure buildup led to an explosive mechanical failure in a 34 cubic meter stainless steel reaction vessel buried in a concrete bunker under building 201 of the radiochemical works at the Tomsk-7 Siberian Chemical Enterprise plutonium reprocessing facility. The vessel contained a mixture of concentrated nitric acid, uranium (8757 kg), plutonium (449 g) along with a mixture of radioactive and organic waste from a prior extraction cycle. The explosion dislodged the concrete lid of the bunker and blew a large hole in the roof of the building, releasing approximately 6 GBq of Pu 239 and 30 TBq of various other radionuclides into the environment. The contamination plume extended 28 km NE of building 201, 20 km beyond the facility property. The small village of Georgievka (pop. 200) was at the end of the fallout plume, but no fatalities, illnesses or injuries were reported. The accident exposed 160 on-site workers and almost two thousand cleanup workers to total doses of up to 50 mSv (the threshold limit for radiation workers is 100 mSv per 5 years).
- June, 1999 — INES Level 2[30] - Ishikawa Prefecture, Japan - Control rod malfunction
-
- Operators attempting to insert one control rod during an inspection neglected procedure and instead withdrew three causing a 15 minute uncontrolled sustained reaction at the number 1 reactor of Shika Nuclear Power Plant. The Hokuriku Electric Power Company who owned the reactor did not report this incident and falsified records, covering it up until March, 2007.[31]
- September 30, 1999 — INES Level 4 - Ibaraki Prefecture, Japan - Accidental criticality
-
- Inadequately trained part-time workers prepared a uranyl nitrate solution containing about 16.6 kg of uranium, which exceeded the critical mass, into a precipitation tank at a uranium reprocessing facility in Tokai-mura northeast of Tokyo, Japan. The tank was not designed to dissolve this type of solution and was not configured to prevent eventual criticality. Three workers were exposed to (neutron) radiation doses in excess of allowable limits. Two of these workers died. 116 other workers received lesser doses of 1 mSv or greater though not in excess of the allowable limit.
- See also: Tokaimura nuclear accident
2000s
- April 10, 2003 — INES Level 3 - Paks, Hungary - Fuel damaged
-
- Partially spent fuel rods undergoing cleaning in a tank of heavy water ruptured and spilled fuel pellets at Paks Nuclear Power Plant. It is suspected that inadequate cooling of the rods during the cleaning process combined with a sudden influx of cold water thermally shocked fuel rods causing them to split. Boric acid was added to the tank to prevent the loose fuel pellets from achieving criticality. Ammonia and hydrazine were also added to absorb iodine-131.[36]
- April 19, 2005 — INES Level 3 - Sellafield, England, United Kingdom - Nuclear material leak
-
- 20 metric tons of uranium and 160 kilograms of plutonium dissolved in 83,000 litres of nitric acid leaked over several months from a cracked pipe into a stainless steel sump chamber at the Thorp nuclear fuel reprocessing plant. The partially processed spent fuel was drained into holding tanks outside the plant.
- November 2005 — INES Level needed - Braidwood, Illinois, United States - Nuclear material leak
-
- Tritium contamination of groundwater was discovered at Exelon's Braidwood station. Groundwater off site remains within safe drinking standards though the NRC is requiring the plant to correct any problems related to the release.[39]
- March 6, 2006 — INES Level 2[40] - Erwin, Tennessee, United States - Nuclear material leak
2010s
See also: Timeline of the Fukushima nuclear accidents
- March 11–20, 2011 - INES Level 7[45](previously rating is 5[46]) as of April 12(A final rating is expected after the situation has been completely resolved).
Fukushima I Nuclear Power Plant, Japan - Overheating, explosions, fire, radioactivity emergency
Main article: Fukushima I nuclear accidents
-
- After the 2011 Tōhoku earthquake and tsunami of March 11, the emergency power supply of the Fukushima-Daiichi nuclear power plant failed. This was followed by deliberate releases of radioactive gas from reactors 1 and 2 to relieve pressure. On March 12, triggered by falling water levels, a hydrogen explosion occurred at reactor 1, resulting in the collapse of the concrete outer structure. Although the reactor containment itself was confirmed to be intact, the hourly radiation from the plant reached 1,015 microsievert (0.1015 rem) - an amount equivalent to that allowable for ordinary people in one year." Residents of the Fukushima area were advised to stay inside, close doors and windows, turn off air conditioning, and to cover their mouths with masks, towels or handkerchiefs as well as not to drink tap water.[57] By the evening of March 12, the exclusion zone had been extended to 20 kilometres (12 mi) around the plant[58] and 70,000 to 80,000 people had been evacuated from homes in northern Japan.[59] A second, nearly identical hydrogen explosion occured in the reactor building for Unit 3 on March 14, with similar effects.[60] A third explosion in the “pressure suppression room” of Unit 2[61] initially was said not to have breached the reactor’s inner steel containment vessel,[62] but later reports indicated that the explosion damaged the steel containment structure of Unit 2 and much larger releases of radiation were expected than previously.[61]
- Disposed rods of reactor Unit 4 were stored outside the reactor in a separate pool which ran dry, yielding fire and risk of serious contamination.[63]
- Staff was brought down from 800 Fukushima, who have been named the "Fukushima 50" by the press.[63] Events are still developing.
- March 11–13, 2011 - INES Level 3,[64] Fukushima II Nuclear Power Plant, Japan - Overheating, possible radioactivity emergency.
-
- After the 2011 Tōhoku earthquake and tsunami of March 11, the cooling systems for three reactors (numbers 1, 2 and 4) of the Fukushima-Daini nuclear power plant were compromised due to damage from the tsunami.[65] Nuclear Engineering International reported that all four units were successfully automatically shut down, but emergency diesel generators at the site were Damaged by the 9.0 magnitude earthquake[66] People were evacuated around 10 kilometres (6.2 mi) from the plant. An evacuation order was issued, because of possible radioactive contamination.[67][68] Events are still developing.